ART 2000 48 Way frames using SPI 235W ATX PSU
units
This ECN only applies to ART2000 4 module frames build between
March 2000 and 27th September 2000
Author
J.B.Toby
Drawing
No
none
Date
27th
September 2000
Reason
for ECN
Power rating increase of the ATX PSU as resulted in reports of nuisance tripping of control fuse at start up only
Special
Parts Required
5A T HBC fuse 20x5mm
Fuse rating sticker : Avolites part number 32-02-9001
Special
Tools Required
none
Work
Required
Replace the control fuses with 5A T HBC fuses.
Situated to the right of the utility breakers, place the “5A T HBC fuse” rating sticker over the “2 A Fuse” legend on the dimmer.