[ Home ] [ What's New ] [ Products ] [ Downloads/Manuals ] [ Technical Support ] [ Gallery ] [ Avo News ] [ About/Contact Us ] [ Marketing ] [ Jokes ] [ Plasa Events ] [ Avo Workshops ] [ Movie Gallery ] [ Avo Forum ] [ Subscribe Me ] [ Avo Shop ] [ Avo Hire ] [ Avo Aid ] [ Missing Items ] [ Links ] [ Search ]
ECN-0124
Work Required
Fit a 470pF capacitor between GND and RST on MAS100. MAS100 is located near the onboard reset switch.
The external reset switch uses connector MAS101.