ECN-0118 |
| Title |
ART 4000 Main Card fixing |
| Equipment |
All ART 4000 modules with
Production date before May 2000 |
| Author |
J.B.Toby |
| Drawing
No |
n/a |
| Date |
9th May 2000
|
| Reason
for ECN |
The main card can work itself out of the ribbon connectors during
transport.
This may result in poorly starting of the ART 4000 after being moved. |
| Special
Parts Required |
Rubber foam strip set.
Part No: 32-02-9000 (1 set for 1 module) |
| Special
Tools Required |
None |
|
Work
Required |
-
Isolate the dimmer system from the mains
supply.
-
Slide the dimmer out of the rack until the slides
lock.
-
Remove the front top cover using a size 2 supa drive
screwdriver.
-
Place the 2 foam strips on the card as per picture
below - do not forget to remove the peel strip!!

- Replace the cover at the breaker side first, and rotate the cover down.
- Check that both strips have "stuck" to the cover before finally fixing the cover to the dimmer.

|
|