|
|
|
[ Home ] [ What's New ] [ Products ] [ Downloads/Manuals ] [ Technical Support ] [ Gallery ] [ Avo News ] [ About/Contact Us ] [ Marketing ] [ Jokes ] [ Plasa Events ] [ Avo Workshops ] [ Movie Gallery ] [ Avo Forum ] [ Subscribe Me ] [ Avo Shop ] [ Avo Hire ] [ Avo Aid ] [ Missing Items ] [ Links ] [ Search ]
|
|
 |




























 |
|
|

|
|
The ART2000i is the latest in the ART2000 range. Designed using the knowledge gained in manufacturing tens of thousands of channels of touring dimming this install system combines the robustness of design from a touring system with the economy of a system which does not need to move (very often at least).
Care has gone into the design to ensure it is easy to install and you can be confident in the knowledge that using the ART2000i in any install design will make the installers job fast as well as giving the client trouble free operation for years to come.
The optional integral patching expands the possibilities of ART2000 including
that of a mixture of touring and install systems, enabling a smaller number of install channels with the knowledge that additional channels can be hired in or purchased as touring systems for larger productions.
The exact specification you need can be built using a number of standard parts, these are listed at the end of the document but please contact us to ensure the most optimum system is put together.
|
Specification
 | 24/48 16amp channels or 12/24 32 Amp channels, or permutations of this. |
 | Size 1000high 500wide 200deep
(Hotpatch increases this, see below). |
 | Twin DMX inputs fully patchable + RDM ready. |
 | Internal memories. |
 | Panic input. |
 | Hotpatch dimmer outputs to install circuits. |
 | RCB protection. |
 | Easily installed, electronics installed separately once building is clean. |
 | Easy commissioning. |
 | Easy disconnect of Live and neutral for building electrical testing. |
 | 240uS rise time. |
 | Proven design, thousands of channels of Art2000 in operation daily. |
Physical
 | The sturdy mainframe is made from 1.5 mm folded, welded and powder coated steel. |
 | The mainframe is 500mm wide 1000mm high and 200mm deep. |
 | The mainframe with optional patch is 500mm wide 1150mm high and 200mm deep. |
 | The mainframe weights 31 Kg. |
 | The 16A power block 16 Kg. |
 | The 32A power block 16 Kg. |
 | Patch panel 6 Kg. |
Channel types
 | The system is build around a mainframe and two power blocks. The power block variants are:-
 | 12 channel 16A 240 μSec rise time choke. |
 | 6 channel 32A 240 μSec rise time choke. |
|
 | The Channel Phase allocation per power block is.
 | Phase 1 channels 1, 4, 7, 10. |
 | Phase 2 channels 2, 5, 8, 11. |
 | Phase 3 channels 3, 6, 9, 12. |
|
 | All channels are rated at 100% duty cycle at 40 °C. |
 | Cooling is achieved by 2 temperature dependant speed controlled fans which are switched off during inactive periods (all channels at 0%). |
 | An optional air filter set is available for the air intake. |
System permutations
A system consists of 1 master mainframe and optionally 1 slave mainframe. Each mainframe can hold 2 powerblocks, each powerblock containing either 12 channels of 16 Amps or 6 channels of 32 Amps per channel.
The possible configurations therefore are:-
Protection
The mainframe can be fitted with optional 30mA RCB protection for each power block.
Mains isolation
 | Single mainframes can be fitted with a 125A mains isolator, which can be locked in the off position. (The diversity factor is 1.) |
 | Master mainframes can be fitted with a 160A mains isolator, which can be locked in the off position. (The diversity factor reduces to 0.62.) |
Mains connection
 | The mains input uses 5 Wago cage clamp capable of receiving 35mm² cables without specialist crimping tools. |
 | The system requires a 3-Phase 4 wire mains connection (TN-S or TN-C-S)
240V P-N/ 415 P-P/ 0V N-E. |
 | The supply needs to be protected with maximum of 125A D type breaker or fused disconnector (160A D type for master slave). |
 | The maximum Icu is 6kA. |
 | The maximum withstand voltage is 2000V. |
Load connection
 | Connection directly to the dimmer circuits |
 | The mainframe load connection to the building wiring is through two multipin connectors allowing easy disconnection of both the neutral and phase connections for periodic wiring tests. |
Using the integral patching option
An optional integral patch panel consists of two outlets per 16 amp dimmer channel and is complemented by a 48 circuit panel for connection to the installed circuits. Connection to this is via four multipin connectors for solid cable ensuring the panel can be closed, or direct into the Wieland connector if stranded building wiring is used. In the patch configuration periodic wiring test neutral and phase disconnection is achieved by unplugging the patch cable.
Installation
The system is specifically designed to be easily installed. The system consists of a cable entry box and the dimming box which contain the electronics etc. These two boxes fit together. The cable entry box is fitted first, and the mounting is very flexible to allow for situations where a hole cannot be drilled in an exact location. Holes for the dimming box are drilled at the same time using a template provided and a plumb line hanging point and tape measure fixing point are provided to ensure the system hangs vertically.
Once the cable entry box has been fitted all the wiring can be completed, whilst the dimmer box is kept in a ‘safe’ environment. Circuits can easily be tested using a test connector which mates with the cable entry box connectors.
The cable entry panel can have 24 PG13.5 knock-outs or be a flat plate which can be easily customized by the installer to suit the local installation.
When the dimming box is required, it is simply hung onto the entry box and screwed into place, and connectors mated to complete the installation. If necessary circuits can still be wired, the hanging of the dimming box does not obstruct the cable termination.
Control system
 | The system is fully digital, no trimming is needed. |
 | Two DMX 512 inputs which can be individually addressed and merged on an HTP basis. |
 | The system is RDM ready via software upgrade using a connection to a laptop computer. |
 | Local channel control is through an intuitive encoder wheel and on-screen level matrix. |
 | 12 memories can be stored and replayed using the encoder wheel and on-screen level matrix. |
 | Breaker and Load Status is displayed on screen, and through RDM when available. |
 | Remote store and replay of memories by any ART dimmer family member |
 | Memory 12 can be controlled by a 12V AC or DC panic input. |
 | Intuitive user interface using a large 42 x 8 character graphics quality backlit LCD display. |
 | Individual channels can be set to any of the available curves. |
 | Individual channels can have a limit level set. |
 | Individual Preheat for each channel. |
 | Plug in Control card for easy maintenance. |
 | Software upgradeable via a PC and download cable. |
|
Example Systems
Note that ALL systems use MCBs (Circuit Breakers) not fuses. The systems described below are only examples configurations there are many more possibilities.
Please contact Avolites for an ideal solution which meets your requirements.
|
24 Channels of dimming, lowest cost system.
| Quantity |
Part |
Description
|
| 1 |
17-82-0010 |
Mainframe
|
| 1 |
17-82-0030 |
PG13
cable entry
|
| 1 |
17-82-0022 |
Patch
Blanking Plate
|
| 2 |
17-82-0060 |
16A
Dimming Blocks
|
24 channels of 16 Amp Dimming with RCB
protection.
| Quantity |
Part |
Description
|
| 1 |
17-82-0010 |
Mainframe
|
| 1 |
17-82-0030 |
PG13
cable entry
|
| 1 |
17-82-0022 |
Cover
Plate
|
| 2 |
17-82-0060 |
16A
Dimming Blocks
|
| 1 |
17-82-0052 |
RCB
protection
|
24
Channels with RCB and Patch.
| Quantity |
Part |
Description
|
| 1 |
17-82-0010 |
Mainframe
|
| 1 |
17-82-0040 |
Patch
system cable entry
|
| 1 |
17-82-0020 |
Patch
|
| 2 |
17-82-0060 |
16A
Dimming Blocks
|
| 1 |
17-82-0052 |
RCB
protection
|
24
Channels with RCB, Patch and mains isolator (full system).
|
Quantity
|
Part
|
Description
|
|
1
|
17-82-0010
|
Mainframe
|
|
1
|
17-82-0040
|
Patch
system cable entry
|
|
1
|
17-82-0020
|
Patch
|
|
2
|
17-82-0060
|
16A
Dimming Blocks
|
|
1
|
17-82-0052
|
RCB
protection
|
|
1
|
17-82-0050
|
Mains
Isolator
|
12
Channels of 16 Amps, 6 channels of 32 Amps, RCB and mains isolator.
| Quantity |
Part |
Description
|
| 1 |
17-82-0010 |
Mainframe
|
| 1 |
17-82-0040 |
Patch
system cable entry
|
| 1 |
17-82-0021 |
Half
Patch
|
| 1 |
17-82-0060 |
16A
Dimming Blocks
|
| 1 |
17-82-0070 |
6
* 32A dimming
|
| 1 |
17-82-0052 |
RCB
protection
|
| 1 |
17-82-0050 |
Mains
Isolator
|
Complete
48 channel system with patch, RCB protection and mains isolator.
This
comprises of two frames, which must be fitted side by side. There is a single
set of electronics and a single mains feed. If a diversity factor of 1 is needed
then two mains feeds can be used, contact Avolites for details and a quotation.
| Quantity |
Part |
Description
|
| 1 |
17-82-0010 |
Mainframe
|
| 1 |
17-82-0011 |
Expansion
Frame
|
| 2 |
17-82-0040 |
Patch
system cable entry
|
| 2 |
17-82-0020 |
Dimmer
Patch
|
| 4 |
17-82-0060 |
16A
Dimming Blocks
|
| 2 |
17-82-0052 |
RCB
protection
|
| 1 |
17-82-0051 |
Mains
Isolator 160A
|
24
channels 16 Amps, 12 Channels 32 Amps, RCB protection and mains isolator.
|
Quantity
|
Part
|
Description
|
|
1
|
17-82-0010
|
Mainframe
|
|
1
|
17-82-0011
|
Expansion
Frame
|
|
2
|
17-82-0040
|
Patch
system cable entry
|
|
1
|
17-82-0020
|
Dimmer
Patch
|
|
2
|
17-82-0022
|
Patch
Blanking Plate
|
|
4
|
17-82-0060
|
16A
Dimming Blocks
|
|
2
|
17-82-0052
|
RCB
protection
|
|
1
|
17-82-0051
|
Mains
Isolator 160A
|
|
Part Numbers and Descriptions
|
|
Part
No
|
Description
|
Picture
|
Notes
|
|
17-82-0010
|
Basic
Stand-Alone Mainframe
|
|
basic
case, controller, lid, manuals installation kit
|
|
17-82-0011
|
Basic
Expansion Frame
|
|
basic
frame, lid, link cables, installation kit
|
|
17-82-0020
|
Full
Wieland ST17 Patch
2
Panels
|

|
dimmer
outlet panel with 48 ST17 sockets patch outlet panel with 48 Wieland
ST17 sockets terminating to 4 Harting 24 Ways connectors
|
|
17-82-0021
|
Half
Wieland ST17 Patch
2
Panels
|

|
dimmer
outlet panel with 24 ST17 sockets patch outlet panel with 24 Wieland
ST17 sockets terminating to 2 Harting 24 Ways connectors, empty patch
sockets blanked
|
|
17-82-0022
|
Patch
Blanking Plate
1
Panel
|

|
blank
plate to cover the dimmer patch out area
|
|
17-82-0030
|
Non
Patch Pg13.5 Cable Entry
|

|
cable
entry with 24 half punched PG13.5 holes, 5 PG13.5 holes for mains inlet
and 4 11mm holes for DMX input
|
|
17-82-0031
|
Non
Patch Plate Cable Entry
|

|
cable
entry with a 1.5mm thick Zintex plate for custom holes(465x140mm)
|
|
17-82-0040
|
Patch
Plate Cable Entry
|

|
cable
entry for patch versions only with a 1.5mm thick Zintex plate for custom
holes(465x140mm)
|
|
17-82-0050
|
125a
Mains Switch
|
|
pad-lockable
125A mains switch
|
|
17-82-0051
|
160a
Mains Switch
|
|
pad-lockable
160A mains switch
|
|
17-82-0052
|
2
Bay RCB Option
|
|
|
|
17-82-0060
|
12x
16A Dimmer Block
|
|
12
x 16A C type breaker 100% duty cycle 240µS rise time
|
|
17-82-0070
|
6x
32A Dimmer Block
|
|
6x
32A C type breaker 100% duty cycle 240µS rise time
|
|
Download the ART2000i Installation
Guide
| File Name |
File Size |
File Format |
| a2k-i-install.pdf |
1,297,598 bytes |
Acrobat |
Click
on filename to open in browser
or
right-click on file name and "Save Target As.." |
|
|

|
|